Red core eCNS600

El Enterprise Core Network System 600 (eCNS600) ha sido desarrollado por Huawei para la Red Evolucionada de Conmutación de Paquetes (EPC) y solo se aplica a las arquitecturas LTE (Evolución a Largo Plazo) o SAE (Evolución de la Arquitectura del Sistema). Integra las funciones de gestión de abonados de SAE-HSS, las funciones de Entidad de Gestión de la Movilidad (MME), las funciones del Gateway Servidor (S-GW)/Gateway PDN (P-GW) y la Función de Políticas y Reglas de Cobro (PCRF). La operación y el mantenimiento del eCNS600 se realiza de manera centralizada.

eCNS600

  • eCNS600

High Integration

The eCNS600 integrates the authentication management functions of the SAE-HSS, the MME functions, and the S-GW/P-GW functions. Installed in a basic subrack, the eCNS600 implements the EPC functions and has the following features:



  • Large capacity
  • Supports 200,000 UEs and large-size data transmission
  • Integrates multiple logical NEs of the EPC, simplifies the network and maintenance, reduces costs, and allows easy deployment.
  • Low power consumption
  • Reduces maintenance costs because the power consumption is 900 W for an eCNS600 deployed in single-board mode


Advanced ATCA Platform

  • ATCA is a hardware standard. It is the name of the architecture standard for the hardware platform rather than the name of a specific product.
  • The eCNS600 uses the Open Standards Telecom Architecture (OSTA 2.0) platform of Huawei, which is a server system featuring high density and high performance based on the ATCA standard architecture. The eCNS600 can provide reliable data processing services for carrier-grade telecommunications applications:
  • High rate:the data exchange bandwidth intra-subrack can reach 2.5 Tbit/s.
  • High reliability:the reliability of the system reaches 99.999%.
  • High scalability:supports the addition of the interfaces on the ATCA board and cascading between subracks
  • Easy to upgrade
  • Efficient management: can manage any part in the system.


High Reliability

  • Backup of important data:the reliability of the system reaches 99.999%.
  • Operation security managemen:Different management privileges are assigned to different users. During the user login, the eCNS600 checks the user identity.
  • Hardware redundancy design
  • Fault prevention
  • The eCNS600 provides protection mechanisms to avoid the following system faults:
  • System power off
  • Misoperation on the system power switch
  • Lightning surge on the system power
  • High voltage and low voltage
  • Short circuit of power supply
  • Current surge and high voltage on the power supply and interfaces
  • System overload control
  • Board lock and unlock, process lock and unlock

Performance Specifications

Parameter Value
Number of subscribers supported by the system 200,000
Number of bearers supported by the system 600,000
Number of eNodeBs supported by the system 1500
Throughputs supported by the system 40 Gbps



Physical Interfaces

Interfaces Physical Characteristics Protocol Maximum Number of Ports
S1 GE IP/MAC 4
10GE IP/MAC 1 to 2(Can be configured)
O&M FE IP 2
SGi GE IP/MAC 4
10GE IP/MAC 1 to 2(Can be configured)



Engineering Parameters

Power input and typical power consumption of the eCNS600table

Parameter Value
Power Input -40 V to -57 V DC
Power consumption for a single board configuration of one subrack 2200 W (maximum) / 600 W (typical)
Power consumption for a single board configuration of two subracks 3500 W (maximum) / 950 W (typical)



Dimensions and weight of the eCNS600 subrack

Parameter Value
Subrack dimensions (H x W x D) 622.3 mm x 442 mm x 437 mm
Subrack weight 21 kg (with empty subrack) < 80 kg (with full configuration)



Noise of an eCNS600

Parameter Value
Noise (acoustic power) ≤ 72 dBA at 23°C (with full configuration)



Operating Environment

Requirements for temperature and humidity

Temperature Relative Humidity
Long-Term Operation Short-Term Operation Long-Term Operation Short-Term Operation
0℃ to +45℃ -5℃ to +55℃ 5% to 85% 5% to 95%
NOTE Temperature and humidity of the ECNS600 are measured 1.5 meters above the floor and 0.4 meters away from the front side of the rack, without protection boards at both the front side and the rear side of the rack.
Short-term operation means that the continuous working hours do not exceed 48 hours or the total working days each year not exceed 15 days.



Other climatic requirements

Item Range
Altitude ≤ 4000 m
Atmospheric pressure 70 kPa to 106 kPa
Temperature change rate ≤ 5℃/min
Solar radiation ≤ 700 W/m²
Heat radiation ≤ 600 W/m²
Wind speed ≤ 1 m/s
IP grade IP50



Reliability Parameters

Name Value
System availability in typical configuration ≥ 99.999%
Mean time between failures (MTBF) ≥ 300000 hours
Mean time to repair (MTTR) ≤ 60 minutes
Redundancy backup mechanism 1+1 backup

eCNS600 deployed in an enterprise network