Capacity Specifications
Item
|
Specifications
|
Maximum number of cells
|
9 cells (10 MHz or 20 MHz)
|
Maximum throughput per cell (20 MHz)
|
2T2R DL:UL=2:2
Downlink rate at the Media Access Control (MAC) layer: 78 Mbit/s(64QAM)
Uplink rate at the Media Access Control(MAC): 18Mbps(16QAM)
|
Maximum throughput per eNodeB
|
Downlink: 450 Mbit/s
Uplink:300 Mbit/s
|
Maximum number of UEs in RRC_CONNECTED mode in an eNodeB:
|
5400
|
Maximum number of data radio bearer (DRB)
|
8
|
BBU3900
Transmission Ports
Board
|
Specifications
|
UMPT
|
One FE/GE electrical port, one FE/GE optical port, and one DB26 port transmitting four links of E1/T1 signals
|
Input Power
Item
|
Specifications
|
Input power
|
–48 V DC (voltage range: –38.4V DC to –57V DC)
|
Physical Specifications
Item
|
Specifications
|
Dimensions (height x width x depth)
|
86 mm x 442 mm x 310 mm (3.46 in. x 17.40 in. x 12.20 in.)
|
Weight
|
≤ 12 kg (26.46 lb) (in full configuration)
|
Environmental Specifications
Item
|
Specifications
|
Working temperature
|
–20°C to +50°C (–4°F to +122°F) (long term)
+50°C to +55°C (122°F to 131°F) (short term)
|
Relative humidity
|
5% RH to 95% RH
|
Ingress Protection (IP) rating
|
IP20
|
Atmospheric pressure
|
70 kPa to 106 kPa
|
RRU3232
Capacity
Frequency Band
|
Frequency Range
|
Carrier Bandwidth
|
Band 38 (2.6 GHz)
|
2570 MHz to 2620 MHz
|
5 MHz or 10 MHz or 20 MHz
|
Band 40 (2.3 GHz)
|
2300 MHz to 2400 MHz
|
5 MHz or 10 MHz or 20 MHz
|
Band 41 (2.6 GHz)
|
2496 MHz to 2690 MHz
|
5 MHz or 10 MHz or 20 MHz
|
3.5 GHz
|
3400 MHz to 3700 MHz
|
5 MHz or 10 MHz or 20 MHz
|
1.8 GHz
|
1755 MHz to 1920 MHz
|
5 MHz or 10 MHz or 20 MHz
|
An RRU3232 supports one carrier with the 5 MHz or 10 MHz or 20 MHz bandwidth.
Output Power
Frequency Band
|
Transmit Power of an RF Channel
|
Total Transmit Power
|
Band 38(2.6GHz)
|
20W
|
80W
|
Band 41(2.6GHz)
|
20W
|
80W
|
Band 40(2.3GHz)
|
20W
|
80W
|
3.5GHz
|
10W
|
40W
|
1.8GHz
|
20W
|
80W
|
Input Power
Item
|
Specifications
|
Input power
|
–48 V DC (voltage range: –36 V DC to –57 V DC}
|
Physical Specifications
Item
|
Specifications
|
Dimensions (height x width x depth)
|
480 mm x 270 mm x 140 mm (18.90 in. x 10.63 in. x 5.51 in.) (18 L without the housing)
485 mm x 300 mm x 170 mm (19.09 in. x 11.81 in. x 6.69 in.) (24.7 L with the housing)
|
Weight
|
≤ 19.5 kg (43.00 lb) (without the housing)
≤ 21 kg (46.31 lb) (with the housing)
|
Environmental Specifications
Item
|
Specifications
|
Working temperature
|
–40°C to +50°C (–40°F to +122°F) (with solar radiation of 1120 W/m2)
–40°C to +55°C (–40°F to +131°F) (without solar radiation)
|
Relative humidity
|
5% RH to 100% RH
|
Absolute humidity
|
0.26 g/m3 to 25 g/m3
|
Atmospheric pressure
|
70 kPa to 106 kPa
|
Operating environment
|
The RRU3232 complies with the following standards:
3GPP TS25.141 V3.0.0
ETSI EN 300019-1-4 V2.1.2 (2003-04) Class 4.1: "Non-weatherprotected locations"
|
Anti-seismic protection
|
NEBS GR63 zone4
|
Ingress Protection (IP) rating
|
IP65
|
Reliability
Item
|
Specifications
|
System availability
|
≥ 99.999%
|
Mean time between failures (MTBF)
|
≥ 155,000 hours
|
Mean time to repair (MTTR)
|
≤ 1 hour
|
System restarting time
|
< 450 seconds
|
eRRU3232
Capacity
Frequency Band
|
Frequency Range
|
Carrier Bandwidth
|
3.7GHz
|
3600MHz~3800MHz
|
5Mhz/10MHz/20MHz
|
5.0GHz
|
4900MHz~5900MHz
|
5Mhz/10MHz/20MHz
|
An RRU3232 supports one carrier with the 5 MHz or 10 MHz or 20 MHz bandwidth.
Output Power
Frequency Band
|
Transmit Power of an RF Channel
|
Total Transmit Power
|
3.7GHz
|
10W
|
40W
|
5.0GHz
|
0.5W
|
2W
|
Input Power
Item
|
Specifications
|
Input power
|
–48 V DC (voltage range: –36 V DC to –57 V DC}
|
Physical Specifications
Item
|
Specifications
|
Dimensions (height x width x depth)
|
480 mm x 270 mm x 140 mm (18.90 in. x 10.63 in. x 5.51 in.) (18 L without the housing)
485 mm x 300 mm x 170 mm (19.09 in. x 11.81 in. x 6.69 in.) (24.7 L with the housing)
|
Weight
|
≤ 19.5 kg (43.00 lb) (without the housing)
≤ 21 kg (46.31 lb) (with the housing)
|
Environmental Specifications
Item
|
Specifications
|
Working temperature
|
–40°C to +50°C (–40°F to +122°F) (with solar radiation of 1120 W/m2)
–40°C to +55°C (–40°F to +131°F) (without solar radiation)
|
Relative humidity
|
5% RH to 100% RH
|
Absolute humidity
|
0.26 g/m3 to 25 g/m3
|
Atmospheric pressure
|
70 kPa to 106 kPa
|
Operating environment
|
The RRU3232 complies with the following standards:
3GPP TS25.141 V3.0.0
ETSI EN 300019-1-4 V2.1.2 (2003-04) Class 4.1: "Non-weatherprotected locations"
|
Anti-seismic protection
|
NEBS GR63 zone4
|
Ingress Protection (IP) rating
|
IP65
|
Reliability
Item
|
Specifications
|
System availability
|
≥ 99.999%
|
Mean time between failures (MTBF)
|
≥ 155,000 hours
|
Mean time to repair (MTTR)
|
≤ 1 hour
|
System restarting time
|
< 450 seconds
|
RRU3251
Capacity
Frequency Band
|
Frequency Range
|
Carrier Bandwidth
|
Band 40(2.3GHz)
|
2300MHz~2400MHz
|
10MHz/20MHz
|
An RRU3251 supports one carrier with the 10 MHz or 20 MHz bandwidth.
Output Power
Frequency Band
|
Transmit Power of an RF Channel
|
Total Transmit Power
|
Band 40(2.3GHz)
|
50W
|
100W
|
Input Power
Item
|
Specifications
|
Input power
|
–48 V DC (voltage range: -34V DC~-60V DC )
|
Physical Specifications
Item
|
Specifications
|
Dimensions (height x width x depth)
|
400mm × 220mm × 140mm (12.5L without the housing)
400mm × 240mm × 160mm (16L L with the housing)
|
Weight
|
≤ 13.5kg (43.00 lb) (without the housing)
≤ 14.5kg (46.31 lb) (with the housing)
|
Environmental Specifications
Item
|
Specifications
|
Working temperature
|
–40°C to +40°C (with solar radiation of 1120 W/m2)
–40°C to +45°C (without solar radiation)
|
Relative humidity
|
5% RH to 100% RH
|
Absolute humidity
|
0.26 g/m3 to 25 g/m3
|
Atmospheric pressure
|
70 kPa to 106 kPa
|
Operating environment
|
The RRU3232 complies with the following standards:
3GPP TS25.141 V3.0.0
ETSI EN 300019-1-4 V2.1.2 (2003-04) Class 4.1: "Non-weatherprotected locations"
|
Anti-seismic protection
|
NEBS GR63 zone4
|
Ingress Protection (IP) rating
|
IP65
|
The DBS3900 addresses site acquisition problems and shortens network deployment time. It enables enterprises to efficiently deploy a wireless network with a low TCO by minimizing the investment in electricity, space, and manpower.
The DBS3900 consists of the BBU3900 and RRU. The BBU3900 is characterized by its small footprint, easy installation, and low power consumption. Therefore, the BBU3900 can be easily installed in a spare space at an existing site. The RRU is compact and lightweight. It can be installed close to an antenna to shorten feeder length and improve system coverage.
Figure 2-10 and Figure 2-11 shows the typical scenarios for installing the DBS3900 outdoors and indoors, respectively.