La BTS3900 soporta la entrada de corriente directa C48 V CD y los modulos correspondientes. Los módulos de la BBU3900 y la CRFU se instalan de manera centralizada en un gabinete de interior. Como la BTS macro de interior más compacta de la industria, la BTS3900 es liviana, pequeña, posee gran capacidad y una buena extensibilidad.
Además, las BTS3900 se pueden apilar y combinar para ahorrar espacio, tal como se muestra en la Figura 1-2.
Technical specifications of the BTS3900
Item
|
Specification
|
Working band
|
Frequency band
|
Receiving band
|
Transmitting band
|
Band class 0
(800 MHz)
|
824 MHz to 849 MHz
|
869 MHz to 894 MHz
|
Band class 15
(AWS)
|
1710 MHz to 1755 MHz
|
2110 MHz to 2155 MHz
|
Band class 1
(1900 MHz)
|
1850 MHz to 1910 MHz
|
1930 MHz to 1990 MHz
|
Band class 14
(US PCS 1.9 GHz)
|
1850 MHz to 1915 MHz
|
1930 MHz to 1995 MHz
|
Band class 6
(2 GHz)
|
1920 MHz to 1980 MHz
|
2110 MHz to 2170 MHz
|
Max. number of carriers supported by one CRFU
|
8
|
Transmitter and receiver specifications
|
Frequency band
|
Receiver sensitivity
|
Max. transmit power
|
Band class 0
(800 MHz)
|
–130 dBm
|
100 W
|
Band class 15
(AWS)
|
–127 dBm
|
80 W
|
Band class 1
(1900 MHz)
|
–127 dBm
|
80 W
|
Band class 14
(US PCS 1.9 GHz)
|
–127 dBm
|
80 W
|
Band class 6
(2 GHz)
|
–127 dBm
|
80 W
|
Transmission ports
|
Max. configuration
|
Number of available ports
|
One CMPT (4E1) and two UTRPs
|
One FE electrical port and one FE optical port (supporting a maximum of 20 E1/T1 links)
|
One CMPT (8E1) and two UTRPs
|
One FE electrical port (supporting a maximum of 24 E1/T1 links)
|
NOTE
The CMPT (8E1) does not support the ATM transmission.
The CMPT (8E1) does not support transmission over the optical port.
|
External clock source
|
GPS/GLONASS, RGPS, 1PPS +TOD, IP CLK
|
Dimensions (height x width x depth)
|
900 mm x 600 mm x 450 mm (35.43 in. x 23.62 in. x 17.72 in.)
|
Weight
|
Fully-configured cabinet: not more than 150 kg (330.75 lb)
|
Input power supply
|
Voltage range for –48 V DC: –57 V DC to –38.4 V DC
|
Power consumption
|
BTS type
|
Configuration
|
Max. power consumption
|
Average power consumption
|
BTS3900
(–48 V DC)
|
S(1/1/1)
|
559 W
|
430 W
|
S(2/2/2)
|
694 W
|
514 W
|
S(3/3/3)
|
884 W
|
647 W
|
S(4/4/4)
|
1037 W
|
749 W
|
NOTE
The power consumption provided in the preceding table is measured when the system is operating in typical configuration at 800 MHz.
The power consumption of the transmission equipment and the charging power consumption of batteries are not included.
The power consumption of BTSs varies with bands and configurations.
|
Temperature
|
–10°C to +55°C (14°F to 131°F)
|
Relative humidity
|
5% RH to 95% RH
|
Absolute humidity
|
(1–29) g/m3
|
Air pressure
|
70 kPa to 106 kPa
|
Protection class
|
IP20
|
Storage environment
|
ETSI EN300019-1-1 V2.1.4 (2003-04) class1.2 "Weatherprotected, not temperature-controlled storage locations"
|
Transportation environment
|
ETSI EN300019-1-2 V2.1.4 (2003-04) class 2.3 "Public transportation"
|
Anti-seismic performance
|
IEC 60068-2-57 (1999-11) Environmental testing – Part 2-57: Tests – Test Ff: Vibration – Time-history method
|
Electromagnetic compatibility
|
The BTS meets the electromagnetic compatibility requirements and complies with the following standards:
R&TTE Directive 1999/5/EC
R&TTE Directive 89/336/EEC
ETSI EN 301489-1/26
ETSI EN 301908-1/5
ITU-R SM.329-10
The BTS passes the European standard certification.
|