GPX-147 -ODF5101

El GPX-147ODF5101 es un distribuidor óptico inteligente (iODF) utilizado en la solución de red de distribución óptica inteligente (iODN) de HUAWEI. Este equipo conecta los cables y sus terminaciones, distribuye, divide y ordena los cables ópticos principales en el sistema de comunicaciones de fibra óptica. Junto con el Intelligent Field (iField) y la red de distribución óptica (ODN) del U2000, permite la ingeniería y la gestión inteligentes de fibras ópticas del iODN.

GPX147-ODF5101

  • GPX147-ODF5101
  • Reliability: The high-density design of the iODF accommodates a maximum of 1944 core wires, the iODF has an arc cabling design, and optical fibers are protected all the way.
  • Modular design: The iODF houses a 19 in. open installation structure and can house various 19 in. rack-mounted units, which facilitates installation and expansion.
  • Easy operation and maintenance: The GPX-147-ODF5101 series is operated from the front and support back-to-back combination and side-by-side combination. This facilitates installation and maintenance.
  • Easy upgrade: The iODF can be upgraded to intelligently manage optical fibers or it can serve as a traditional optical distribution frame (ODF).
  • Intelligent management: The iODF can identify and manage optical fiber patching and connection.
  • Intelligent engineering: The iFAT controls indicator states to provide engineering guidance and eliminate engineering faults, verifies engineering data to ensure correct engineering at a time, and records data.

Application Scenario

Model GPX147-ODF5101- CH2/FH2 GPX147-ODF5101-CH9/FH9
Dimensions (H x W x D) mm 2200 x 1200 x 300 2200 x 900 x 300 1600 x 900 x 300
Available installation space 45 U 40 U 26 U
Installation In a 19 in. rack (standard) In a 19 in. rack (standard) In a 19 in. rack (standard)
Capacity (core) In the integrated splicing and termination scenario: 1944 core
In the separated splicing and termination scenario:
line splicing: 1296 core
line distribution: 1296 core
In the integrated splicing and termination scenario: 1728 core
In the separated splicing and termination scenario:
line splicing: 1296 core
line distribution: 1080 core
In the integrated splicing and termination scenario: 1080 core
In the separated splicing and termination scenario:
splicing: 864 core
distribution: 648 core
Materials Sheet metals Sheet metals Sheet metals

Item Specifications
Bending radius Equal to or greater than 30 mm (1.18 in.)
Operating temperature Long term: -5°C to +45°C (23-113°F)
Short term: -25°C to +55°C (-13°F to +131°F)}
Storage temperature -25°C to +55°C (-13°F to +131°F)
Transportation temperature Ventilation: -40°C to +40°C (-40°F to +104°F)
Non-ventilation: -40°C to +70°C (-40°F to +158°F)
Humidity 5%-85% RH (non-condensing)}
Atmospheric pressure 70-106 kPa

Category Description
Structure component Cabinet, optical cable stripped module, optical fiber post, splicing subrack, operating platform, and base
Intelligent component Intelligent unit, middle termination unit, compact optical splitter, electronic identification (eID) tool, and eID patch cord, eID converter.

GPX-147-ODF5101-General Module

Intelligent Unit

Features:


  • The 5 U (222.25 mm or 8.75 in.) intelligent unit case is installed in a 19 in. wide cabinet and has a compact structure.
  • It is configured with a control board and service boards.
  • It is used in the integrated splicing and termination unit, cable distribution unit , and slotted optical splitter unit.

Specifications:


Model Dimensions (H x W x D) mm Installation Capacity (core)
GPX147-SR5101-5U 5U×482×265 19’’ 216 (18 slot)
GPX147-SR5102-5U 5U×482×265 19’’ 144 (12 slot)

MPU

Features:


  • Installed in a 19 in. cabinet.
  • Provides management ports inside the cabinet or rack to control and manage control boards in a centralized manner.
  • Provides communications ports outside the cabinet or rack to communicate over a laptop or personal digital assistant (PDA).

Specifications:


Model Dimensions (H x W x D) mm Installation
MPU3101C-AC-1 U 1 U x 442 x 265 19”
MPU3101C-DC-1 U 1 U x 442 x 265 19’’
MPU3101D-AC-1 U 1 U x 442 x 265 19’’
MPU3101D-DC-1 U 1 U x 442 x 265 19’’
MPU3101B-AC-1 U 1 U x 442 x 265 19’’
MPU3101B-DC-1 U 1 U x 442 x 265 19’’

GPX-147-ODF5101-General Module

Splicing Unit

Features:


  • The base can be rotated by 90 degrees clockwise for ease of splicing.
  • Cables are routed into the splicing unit from the right. The splicing unit can house 24 splicing tray modules with a maximum of 432 core

Specifications:


Model Dimensions (H x W x D) mm Installation Capacity (core)
GPX147-SR2101-4U 4U×442×265 19’’ 432

Middle termination unit

Features:


  • Installed in a 19 in. cabinet.
  • Separates the optical line terminal (OLT) area from the service area with a maximum of 192 core

Specifications:


Model Dimensions (H x W x D) mm Capacity
GPX147-FTM5101-192 6U×482×248 192 core (16 card slotting bars)

Operating platform

Features:


  • Installed in a 19 in. cabinet.
  • Facilitates engineering and bears 10 kg (22.05 lb) loads.
  • Allows a 14 in. laptop to be opened by 90 degrees.

Specifications:


Model Dimensions (H x W x D) mm Installation
GPX147-ITC2101-1U 1U×442×265 19’’