PowerCube 1000-Diesel Hybrid

PowerCube 1000-D is applicable in off-grid&poor grid areas.This solution solves the problem of low conversion efficiency, high fuel consumption,heavy maintenance and component theft.


Saving TCO

Industry-leading EPS-D / battery scheduling strategy optimizes the EPS-D. Operating status and reduces its operation time. This allows the PowerCube 1000 to save fuel 40%-60% and reduce EPS-D. Maintenance cost by 50%-70% compared to traditional double EPS-D solution.



Intelligent management, saving maintenance

  • EPS-D 1000 hours overhaul, reduce maintenance ;
  • Support remote parameter management and setting ,support parameter series renewal;
  • Supports real-time statistics and management of key parameters such as solar production, load consumption, load current, system voltage, battery current and DG total DC energy production;
  • Support history data query and KPI index report and analysis;
  • Anti-theft design.


Single platform, smooth expansion

  • Modular design, easy expansion without interrupting business;
  • System support smooth evolution of different hybrid power solutions (solar solution, Grid hybrid solution, etc.).


Fast deployment, saving site construction time

  • Small dimension and volume, less land surface, easy to deploy, easy to install;
  • Integrated design, facilitating engineering work such as operation, cabling.


Support reuse EPS-D/ATS/Power Supply System

Existing equipments and systems can be reused to protect customer’s investment and save CAPEX.



Support Indoor/Outdoor scenarios

Flexible configuration, suits for indoor/outdoor scenarios, saving CAPEX.



Various cooling option, reducing EPS-D running time and saving fuel

Support FCS(Free Cooling System), DC air conditioner and reusing AC air conditioner, reducing EPS-D running time, saving OPEX.



Value-added services

  • E-tag for remote property management;
  • Electric expenditure calculation for sharing sites;
  • Refuel reminding.


PowerCube-D D502A D502A1 D502A2 D703A1
Configuration
EPM Capacity (KW) - - - -
Fuel Tank Capactiy (L) - - - -
Power Supply Unit Capacity (A) 50A*3 50A*3 50A*3 50A*4
Cooling Method for Integrated Controller & Converter Heat Exchange Heat Exchange Heat Exchange Heat Exchange
Cooling Method for Energy Storage System DC Air-conditioner DC Air-conditioner DC Air-conditioner DC Air-conditioner
Energy Storage System Type ESS-D ESS-D ESS-D ESS-D
Energy Storage System Capacity (KWh) 28.8 40.3 47 57.6
Power Distribution Secondary load (-48v) 80A*2(MCB),20A*2(MCB) 80A*2(MCB),20A*2(MCB) 80A*2(MCB),20A*2(MCB) 80A*2(MCB),20A*2(MCB)
Primary load (-48v) 32A*1(MCB),16A*3(MCB),10A*1 (MCB) 32A*1(MCB),16A*3(MCB),10A*1 (MCB) 32A*1(MCB),16A*3(MCB),10A*1 (MCB) 32A*1(MCB),16A*3(MCB),10A*1 (MCB)
Physical Specifications
Dimensions (W x D x H ) (mm) 1755 x 1135 x 2110 1755 x 1135 x 2110 1755 x 1135 x 2110 1755 x 1135 x 2110
Weight (Kg) <1712 <2360 <2609 <2872
Customer Equipment Space/ Heat Consumption 13U / 750W 13U / 750W 13U / 750W 13U / 750W
Protection Level Integrated Inverter & Converter System IP55 IP55 IP55 IP55
Energy Plant System - - - -
Energy Storage System IP55 IP55 IP55 IP55
Operating Conditions
Operating Temperature -20~+50℃ -20~+50℃ -20~+50℃ -20~+50℃
Storage Temperature -40~+70℃ -40~+70℃ -40~+70℃ -40~+70℃
Operating Relative Humidity 5%~95% 5%~95% 5%~95% 5%~95%
Opreating Altitude 0~4,000m (derated when >2,000m) 0~4,000m (derated when >2,000m) 0~4,000m (derated when >2,000m) 0~4,000m (derated when >2,000m)
Atmospheric Pressure 70~106KPa 70~106KPa 70~106KPa 70~106KPa
Wind-resistant Level ≤50m/s ≤50m/s ≤50m/s ≤50m/s
Functions
1000hrs EPM Maintenance Interval - - - -
Fuel Level Detection - - - -
Automatic Alarm for Fuel Abnormal - - - -
Fuel Mixed with Water Detection - - - -
Double Fold of Anti-theft Design for EPM Fueling Ports (Passive) - - - -
Four Fold of Fuel Anti-theft Design (Active) - - - -
Automatic Notice for Refueling - - - -
All-in-one Control Design
Remote Upgrade of Controller
LLVD & BLVD
Statistics on Num of Charge & Discharge, Sum of Discharge Capacity
Real Time Monitor Voltage, Current, Temperature of Energy Storage System
Surge Protection Design for Signal & Power Interface
EPM Maintenance Reminding - - - -
IP,GPRS, SMS Networking ¡ ¡ ¡ ¡
Real-time Data Monitoring ¡ ¡ ¡ ¡
Historical Data & Alarms Tracking System ¡ ¡ ¡ ¡
KPI Performance Reports ¡ ¡ ¡ ¡
Remote Configuration & Operation ¡ ¡ ¡ ¡
Login via Website ¡ ¡ ¡ ¡



PowerCube-D D532A1 D532A3 D532A5
Configuration
EPM Capacity (KW) 10 10 10
Fuel Tank Capactiy (L) 800 800 800
Power Supply Unit Capacity (A) 50A*3 50A*3 50A*3
Cooling Method for Integrated Controller & Converter Heat Exchange Heat Exchange Heat Exchange
Cooling Method for Energy Storage System DC Air-conditioner DC Air-conditioner DC Air-conditioner
Energy Storage System Type ESS-D ESS-D ESS-D
Energy Storage System Capacity (KWh) 28.8 40.3 47
Power Distribution Secondary load (-48v) 80A*2(MCB),20A*2(MCB) 80A*2(MCB),20A*2(MCB) 80A*2(MCB),20A*2(MCB)
Primary load (-48v) 32A*1(MCB),16A*3(MCB),10A*1 (MCB) 32A*1(MCB),16A*3(MCB),10A*1 (MCB) 32A*1(MCB),16A*3(MCB),10A*1 (MCB)
Physical Specifications
Dimensions (W x D x H ) (mm) 3555x 1135 x 2110 3555x 1135 x 2110 3555x 1135 x 2110
Weight (Kg) <2612 <3260 <3509
Customer Equipment Space/ Heat Consumption 13U / 750W 13U / 750W 13U / 750W
Protection Level Integrated Inverter & Converter System IP55 IP55 IP55
Energy Plant System IP23 IP23 IP23
Energy Storage System IP55 IP55 IP55
Operating Conditions
Operating Temperature -5~+50℃ -5~+50℃ -5~+50℃
Storage Temperature -40~+70℃ -40~+70℃ -40~+70℃
Operating Relative Humidity 5%~95% 5%~95% 5%~95%
Opreating Altitude 0~4,000m (derated when >1,000m) 0~4,000m (derated when >1,000m) 0~4,000m (derated when >1,000m)
Atmospheric Pressure 70~106KPa 70~106KPa 70~106KPa
Wind-resistant Level ≤50m/s ≤50m/s ≤50m/s
Functions
1000hrs EPM Maintenance Interval
Fuel Level Detection
Automatic Alarm for Fuel Abnormal
Fuel Mixed with Water Detection
Double Fold of Anti-theft Design for EPM Fueling Ports (Passive)
Four Fold of Fuel Anti-theft Design (Active)
Automatic Notice for Refueling
All-in-one Control Design
Remote Upgrade of Controller
LLVD & BLVD
Statistics on Num of Charge & Discharge, Sum of Discharge Capacity
Real Time Monitor Voltage, Current, Temperature of Energy Storage System
Surge Protection Design for Signal & Power Interface
EPM Maintenance Reminding ¡ ¡ ¡
IP,GPRS, SMS Networking ¡ ¡ ¡
Real-time Data Monitoring ¡ ¡ ¡
Historical Data & Alarms Tracking System ¡ ¡ ¡
KPI Performance Reports ¡ ¡ ¡
Remote Configuration & Operation ¡ ¡ ¡
Login via Website ¡ ¡ ¡

Remark : "●"Mandatory, "○"Optional,"-" None


EPS(Energy Plant System):

EPS (Energy Plant System) is the power source, including commercial grid power, solar power and D.G power.



ICC (Integrated Controller and Converter):

The ICC consists of a cabinet, a temperature system, ECC500, an integrated distribution unit (IDU), power supply unit (PSU). The cabinet has both the front and back doors.



ESS (Energy Storage System):

The ESS consists of batteries and a cabinet which are integrated together with ICC inside one cabinet.



OSS (Operation Support System):

The OSS is composed of NMC (NetEco), Network(GPRS/IP), ECC500 etc, ECC500 collects power and environment parameter through serial port and I/O port and then communicates with NMC through network. It supports data collection, data transmission and data display.