Wall-mounted Power - Huawei Products
Under Construction!

Prompt

You have not logged in. Want to enter the login page?

Yes No

Prompt

Sorry that you are not authorized to download this document.

Apply Previous

Register an account

  • *
  • *
  • *
  • *
  • *
  • I agree that Huawei representatives may contact me.
  • I agree to receive information on Huawei products by email.
  • Terms of UsePrivacy Policy

If you already have a Huawei account, please login to download

Wall-mounted Power

Wall-mounted power system mainly used in 2G/3G coverage, microwave coverage, WLAN equipments power supply. It supports 220V single phase or 110V dual-wire input. It has the features of compact design, intelligent monitoring, flexible backup of power, and smooth expansion.


  • Extra wide range of AC input voltage from 85V to 300V
  • High rectifier efficiency more than 96% helps to save energy
  • Wide working temperature range of rectifier from -40℃ to 75℃
  • Rectifier MTBF≥ 500,000 hours
  • Online-swappable rectifier provides easy installation and maintenance
  • Intelligent battery management and protection helps to prolong battery lifespan
  • Anti-reverse connection of battery polarity function
  • Support site environment monitoring and remote management through dry contact, serial interface
  • Intelligent control module with LCD provides visible monitoring
  • Thorough alarms and protection against failures
  • Capable of providing uninterrupted AC and DC power simultaneity with inverter inside
  • Compact cabinet supports wall-mounted, ground-stand and pole-mounted installation
  • Well environmental adaptability with IP55 class protection and low noise for outdoor cabinet



Type TP4860C
System specification Dimension 450mm(W, excluding 50mm protuberant part on the vent port) ×630mm(H)×300mm(D)
Weight ≤32kg(without rectifier and battery)
Rated capacity 30A/60A (compatible with 15A and 30A module) , 700WAC (with optional inverter)
Cooling mode Direct ventilation
Maintenance mode Front maintenance, supporting module-level replacement
Cabling mode Cable outlet from the bottom of the cabinet
Installation mode Wall-mounted/pole-mounted/land-stand
Protection level IP55
Battery (optional) Built-in 40Ah Lithium battery or 20Ah/40Ah VRLA battery, 40Ah battery can be parallel connected through battery cabinet
Environmental specification Operating temperature -40℃~+45℃
Operating humidity 5%~95%(non-condensing)
Altitude 0~4000m (at the altitude from 2000m to 4000m, the temperature declines by 1ºC for each increase of 200m in altitude)
AC distribution AC input Single phase (L,N,PE) or 110V dual line (L1,L2,PE)
Only support single phase 220V, 50Hz when AC configured
inverter output (optional) 1000VA/700W, 3×10A/1P MCB
AC input voltage 85~300VAC, rated: 220VAC
AC input frequency 45~66Hz, rated: 50Hz/60Hz
AC SPD 20/40kA (8/20µs)
DC SPD Differential mode: 10kA, 8/20µs, Common mode: 20kA, 8/20µs
Signal port SPD Differential mode: 3kA, 8/20µs, Common mode: 5kA, 8/20µs
DC distribution Output voltage -42~-58VDC, default value: -53.5VDC
Maximum output power 4800W
Battery branch 1×63A/1P (MCB)
BLVD 3×16A/1P (MCB)
Rectifier module Efficiency >96%
Input voltage 85~300VAC, rated: 220VAC
Monitoring unit Sensors interface Gate, water, smoke, battery temperature, environmental temperature & humidity
Digital input 4 branches
Alarm output 4 branches
Communication port RS485/RS232
Battery (optional) Rated capacity 20Ah VRLA battery 40Ah VRLA battery 40Ah Li-battery
Weight 6.35kg×4 14.6Kg×4 25kg
Nominal voltage 12V 12V 48V


Wall-mounted power includes power cabinet and rectifiers, inverter, VRLA battery, lithium battery, heater box and sensors..


Power cabinet: includes AC distribution, DC distribution and monitoring unit.


Rectifier: rectifier’s type and data are based on load power and battery’s most charge function to make sure.


Inverter: it is needed when AC input is required. It can offer 1000VA (700W).


Sensor: battery temperature & humidity sensor is optional,.


VRLA battery: according to load and backup time to choose battery, there are 20AH and 40AH to be chosen.


Lithium battery: 40AH to be chosen.


Heater: it is configured when the temperature of environment is below -10℃.



DOCUMENTATION CENTER NEWS ROOM CASE STUDIES VIDEO ZONE PUBLICATIONS SHARE